Lighted
Numbers Installation Instructions
- Mark location
for the mounting holes on the wall surface for the installation
of the illuminator frame. Drill and install screw anchors (supplied).
Drill
1/4" diameter wire clearance hole through the wall surface
as shown in Figure No. 1.
- The
illuminator is furnished with four 14 volt lamps (NO. 1815) and
requires 10 volt-amperes at 14 volts from a bell type transformer.
If the illuminator is to be operated from the same transformer
as a bell or chime installation, a transformer rating of 30 VA
is recommended.
- Run
two (2) separate, NO. 18, or larger, bell wires into the 1/4"
diameter clearance hole through the wall surface, connecting the
far ends to the secondary terminals of the bell transformer as
shown in Figure No. 2.
ALTERNATIVE
POWER SUPPLY
Use a 10VA (Class II) 14 Volt transformer available on the order
page.
- Remove approximately
1/4" of installation from the exposed end of each wire. Insert
each wire end into the barrel end of a lug terminal (supplied)
and crimp securely with pliers.
- Connect one
(1) wire to each terminal with machine screws (supplied).
- Assemble
Ceramic numbers in proper order in the weatherproof cardboard
insert (supplied).
- Place insert
into the "ILLUMINATOR FRAME".
- Secure illuminator
frame to mounting surface with the two (2) mounting screws (supplied).